1.使用keil調(diào)試過程不可以開啟看門狗,否則會報錯:nu_Link ice:cmderror-get register data error
2.官方方法,沒有深入嘗試,目前的解決方法是,kill掉所有的端點(diǎn),再退出調(diào)試
μVISION: Error: Encountered an improper argument
Information in this knowledgebase article applies to:
MDK-ARM Version 5.x
SYMPTOM
Under some circumstances, an error dialog with the text Encountered an improper argument might show up when you exit a debug session. If this happens, μVision needs to be terminated with the Windows Task Manager. In most cases, customers with Asian Windows versions are affected by this issue when Asian characters are used in the project path.
CAUSE
The μVision 5 debugger is currently not able to process DWARF debug information which contains folder or file names with UTF-8 characters.
RESOLUTION
Use only ASCII characters in the folder and file names of your project and all your source files and libraries.
SEE ALSO
Refer to μVision: Error: Encountered an improper argument